How often do I need to replace the lubricating oil of the NMRV reducer?


Comparison Table of Lubricating Oil Selection for NMRV Reducer

NMRV machine base modelRecommended lubricant gradeFirst oil change cycleSubsequent oil change cycleApplicable ambient temperature
25-90 (aluminum shell version)ISO VG320 synthetic gear oilContinuous operation for 500 hoursEvery 6000 hours-15℃ ~ +40℃
110/130/150 (cast iron shell version)AGIP BLASIA 460 Industrial Gear OilOperate for 150-400 hoursNot exceeding 4000 hours-5℃ ~ +40℃
Special low-temperature working conditionsLow freezing point synthetic gear oilExecute according to the regular cycleExecute according to the regular cycleBelow 0 ℃ environment

Prohibition rule: Mixing of lubricating oils of different grades is prohibited, only oils of the same grade but different viscosities are allowed to be mixed.

Oil temperature limit: During normal operation, the maximum temperature of the lubricating oil should be controlled within 85 ℃. If it exceeds this value, the machine should be shut down for troubleshooting.